logos conahcyt-ciqa

ABSTRACTS POR TÓPICO

S1. Polímeros para Aplicaciones Avanzadas

PREPARATION AND CHARACTERIZATION OF A CHITOSAN-HPMC AND GLYCEROL HEMOSTATIC SPONGE FOR DENTAL APPLICATIONS
Leopoldo Antonio de Quesada Iraizoz1, Jesus Manuel Quiroz Castillo2, José Carmelo Encinas Encinas2, María Mónica Castillo Ortega2, Dora Evelia Rodríguez Félix2, Carmen María López Saiz3, Antonio Iraizoz Colarte4, Antonio Rascón Carreaga5, Alejandro Abraham Leyva Verduzco2
1Universidad de Sonora, Dipm: Departamento de Investigación En Polímeros y Materiales., Mexico. 2Universidad de Sonora, DIPM, Mexico. 3Universidad de Sonora, DIPA, Mexico. 4Universidad de la Habana, IFAL, Cuba. 5Universidad de Sonora, Facultad Interdisciplinaria Ciencias Biologicas y salud, Mexico.


Bleeding is a leading cause of mortality in accidents, general surgeries, and dental procedures. In this context, polysaccharides—particularly cellulose and chitosan—are highly valued for their renewability, biodegradability, low cost, and minimal environmental impact. These polymers exhibit hydrophilic properties and are degradable by human enzymes, making them both biocompatible and biodegradable, two key features required for biomedical applications. This study aimed to develop a biodegradable, micro/nano-structured, porous hemostatic sponge composed of chitosan and cellulose (CS/HPMC/Gl), produced via the freeze-drying method for potential biomedical use.

The CS/HPMC/Gl composite was created by blending a 2% chitosan solution in acetic acid with a 2% hydroxypropyl methylcellulose (HPMC) solution, dispersed in 2% glycerol (Gl). This formulation significantly improved the mechanical properties and pore distribution of the material, resulting in an average pore size of 190.3 ± 32.8 μm and a density of approximately 2.3 mg/cm³. The material demonstrated a swelling rate of 19.4 within the first minute of incubation, and a uniaxial compression test produced a value of 118.45 kPa.

 An in vitro bacterial inhibition assay, performed with Staphylococcus aureus and Escherichia coli, suggested that the material has an antibacterial effect, particularly against S. aureus. Furthermore, cytotoxicity testing on hFOB119 osteoblast cells revealed no adverse impact on cell viability. After eight days of simulated biodegradation, the sponge exhibited nearly complete degradation (99.16%) in the presence of lysozyme, while degradation in PBS reached 63.56%.
 The CS/HPMC/Gl sponges displayed favorable characteristics, as confirmed by FTIR analysis, thermogravimetric studies, and morphological evaluations, including both micrometric and nanometric pores. The material’s swelling capacity, mechanical robustness, and biodegradation behavior highlight its potential for in vivo biological testing and wider biomedical applications.


Keywords: Biomaterial, Chitosan, hydroxypropilmetilcellulose

Acknowledgment:

We would like to express our sincere gratitude to the National Council of Science and Technology (CONAHCYT) of Mexico for their financial support, which made this research possible. We also extend our thanks to the staff of the Department of Research in Polymers and Materials (DIPM) at the University of Sonora (UNISON) for their invaluable technical assistance and contributions throughout the development of this project.

Presenting authors email: leopoldo.dequesada5@gmail.com
Descargar PDF